Hanbell

Hanbell Compressors

ThermaGroup stock a range of new compressors from Hanbell. ThermaCom are a Hanbell agent with offices located in both Reading and Nottingham.

ThermaCom are able to supply re-manufactured Hanbell compressors to locations all over the UK and to an increasing number of countries overseas.

 

Hanbell Compressors

We supply a range of over 50 Hanbell remanufactured refrigeration Compressors, including the RC2 Semi-Hermetic range. We also stock a variety of Hanbell Screw Compressors. Hanbell Compressors are specially designed for both refrigeration and air conditioning. Each compressor being highly efficient and reliable for it's particular purpose. Hanbell are currently the market leader in it's area, proving the quality of the compressors they provide.

 

Type: Screw Compressor

Application & nominal capacity:
A - R134a 50hz: 61
B - R470C 50hz: 93
B - R134a Inverter 70hz: 85
AV - Inverter R134a @ 60hz: 73

Displacement M3/hr @ 50hz: 98

Base Voltage: 400vac 50hz

Ancillary Voltage: 110v or 230v

Type: Screw Compressor

Application & nominal capacity:
A - R134a 50hz: 112
B - R470C 50hz: 160
B - R134a Inverter 70hz: 157
AV - Inverter R134a @ 60hz: 135

Displacement M3/hr @ 50hz: 180

Base Voltage: 400vac 50hz

Ancillary Voltage: 110v or 230v

Type: Screw Compressor

Application & nominal capacity:
A - R134a 50hz: 120
B - R470C 50hz: 180
B - R134a Inverter 70hz: 168
AV - Inverter R134a @ 60hz: 145

Displacement M3/hr @ 50hz: 193

Base Voltage: 400vac 50hz

Ancillary Voltage: 110v or 230v

Type: Screw Compressor

Application & nominal capacity:
A - R134a 50hz: 161
B - R470C 50hz: 239
B - R134a Inverter 70hz: 225
AV - Inverter R134a @ 60hz: 194
AVI - Inverter @ 70hz with VI optimisation: 226

Displacement M3/hr @ 50hz: 257

Base Voltage: 400vac 50hz

Ancillary Voltage: 110v or 230v

Type: Screw Compressor

Application & nominal capacity:
A - R134a 50hz: 190
B - R470C 50hz: 283
B - R134a Inverter 70hz: 266
AV - Inverter R134a @ 60hz: 229
AVI - Inverter @ 70hz with VI optimisation: 267

Displacement M3/hr @ 50hz: 293

Base Voltage: 400vac 50hz

Ancillary Voltage: 110v or 230v

Type: Screw Compressor

Application & nominal capacity:
A - R134a 50hz: 220
B - R470C 50hz: 327
B - R134a Inverter 70hz: 308
AV - Inverter R134a @ 60hz: 265
AVI - Inverter @ 70hz with VI optimisation: 309

Displacement M3/hr @ 50hz: 339

Base Voltage: 400vac 50hz

Ancillary Voltage: 110v or 230v

Type: Screw Compressor

Application & nominal capacity:
A - R134a 50hz: 244
B - R470C 50hz: 357
B - R134a Inverter 70hz: 342
AV - Inverter R134a @ 60hz: 294

Displacement M3/hr @ 50hz: 366

Base Voltage: 400vac 50hz

Ancillary Voltage: 110v or 230v

Type: Screw Compressor

Application & nominal capacity:
A - R134a 50hz: 266
B - R470C 50hz: 368
B - R134a Inverter 70hz: 372
AV - Inverter R134a @ 60hz: 320
AVI - Inverter @ 70zh with VI optimisation: 374

Displacement M3/hr @ 50hz: 407

Base Voltage: 400vac 50hz

Ancillary Voltage: 110v or 230v

Type: Screw Compressor

Application & nominal capacity:
A - R134a 50hz: 303
B - R470C 50hz: 456
B - R134a Inverter 70hz: 424
AV - Inverter R134a @ 60hz: 365
AVI - Inverter @ 70zh with VI optimisation: 426

Displacement M3/hr @ 50hz: 471

Base Voltage: 400vac 50hz

Ancillary Voltage: 110v or 230v

Type: Screw Compressor

Application & nominal capacity:
A - R134a 50hz: 326
B - R470C 50hz: 482
B - R134a Inverter 70hz: 456
AV - Inverter R134a @ 60hz: 393

Displacement M3/hr @ 50hz: 508

Base Voltage: 400vac 50hz

Ancillary Voltage: 110v or 230v

Type: Screw Compressor

Application & nominal capacity:
A - R134a 50hz: 358
B - R470C 50hz: 533
B - R134a Inverter 70hz: 501
AV - Inverter R134a @ 60hz: 430
AVI - Inverter @ 70hz with VI optimisation: 502

Displacement M3/hr @ 50hz: 549

Base Voltage: 400vac 50hz

Ancillary Voltage: 110v or 230v

Type: Screw Compressor

Application & nominal capacity:
A - R134a 50hz: 381
B - R134a Inverter 70hz: 533
AV - Inverter R134a @ 60hz: 458

Displacement M3/hr @ 50hz: 582

Base Voltage: 400vac 50hz

Ancillary Voltage: 110v or 230v

Do you know which compressor performs best
for your needs?

Compair our Compressors

If you can't find the brand or model of compressor you are looking for, please contact ThermaGroup today for current stock and supply information.

Contact us Call us on: +44 (0)118 9181 400

We supply and remanufacture compressors and offer repairs on leading compressor brands found throughout the HVAC industry. We also specialise in chiller and air-conditioning repair, servicing and remanufacturing.

View full product range

 

UK Offices

Want to discuss a potential project? Come and have a chat with us.

 

Reading

Preston Road
Reading
Berkshire
RG2 0BE
United Kingdom

Telephone: +44 (0)118 9181 400
Fax: +44 (0)118 9181 409
Email: This email address is being protected from spambots. You need JavaScript enabled to view it.

Nottingham

Celsius House
Summit Close
Kirkby In Ashfield
NG17 8GJ
United Kingdom

Telephone: +44 (0)118 9181 400
Fax: +44 (0)118 9181 409
Email: This email address is being protected from spambots. You need JavaScript enabled to view it.